MEP: plumbing & electrical CAD blocks

MEP CAD blocks for plumbing, heating, ventilation, electrical and fire protection: traps, manholes and a septic tank excavation, a tank water heater and a boiler, duct systems, a transformer and a grounding rod, fire extinguishers and hose cabinets, and elevator sections. Most are sections and details at full size for construction documents, with a few equipment elevations for mechanical rooms and utility closets.

Every one downloads as a DWG or DXF in inches and millimeters, and as a PDF, PNG or SVG.

10CAD blocks 5 formatsDWG in + mm
Bottle trap CAD block in front elevation, 9⅛″ × 9⅞″Bottle Trap · 9⅛″ × 9⅞″ · outlet height 18″ 9⅞″250 mm Bottle Trap Panel radiator CAD block in side elevation, 4″ × 35″Panel Radiator · 4″ × 35″ · panel bottom 6″ 2′-11″889 mm Panel Radiator 6′-0″1829 mm 6 ft person Fire extinguisher CAD block in front elevation, 9⅝″ × 22⅝″Fire Extinguisher · 9⅝″ × 22⅝″ 1′-10⅝″574 mm Fire Extinguisher Fire hydrant CAD block in front elevation, 17⅜″ × 48⅞″Fire Hydrant · 17⅜″ × 48⅞″ 4′-0⅞″1243 mm Fire Hydrant +1′-6″+457 mmOutlet +6″+152 mmPanel bottom
Point at a piece to see its size, click to open it. Every piece is drawn at its real size next to a 6 ft person.

Designing, not drafting? These mep: plumbing & electrical blocks also come as SVG vectors, PNG files with a transparent background and print-ready PDFs.

1 scenes · point at a piece to see its size

Fire protection Elevation · to scale

Fire extinguisher CAD block in front elevation, 9⅝″ × 22⅝″Fire Extinguisher · 9⅝″ × 22⅝″ 1′-10⅝″574 mm Fire Extinguisher 6′-0″1829 mm 6 ft person Fire hydrant CAD block in front elevation, 17⅜″ × 48⅞″Fire Hydrant · 17⅜″ × 48⅞″ 4′-0⅞″1243 mm Fire Hydrant

About mep: plumbing & electrical CAD blocks

Plumbing covers a bottle trap and drum traps, a manhole section, a septic tank excavation 21′-11⅞″ (6702 mm) wide, a sewage pump chamber, a typical bathroom plumbing scheme and a tank water heater 21″ × 50″ (533 × 1270 mm). Heating and ventilation add a panel radiator, a residential heating boiler, a ventilation duct system and a heating system symbols legend. Electrical has an oil-filled transformer, a grounding rod and weld and an electrical conduit trench; fire protection a fire extinguisher, a fire hose cabinet and a fire hydrant; and vertical transport an elevator cabin 78¾″ × 74″ (2000 × 1880 mm) with its shaft and doors in section.

Code figures worth keeping at hand: a fixture trap holds a water seal of 2–4″ (51–102 mm) (IPC 1002.4); extinguishers up to 40 lb (18 kg) mount with the top no higher than 5′ (1524 mm) (NFPA 10); hydrants keep 3′ (914 mm) of clear space around them (IFC 507.5.5); and buried PVC conduit generally needs 18″ (457 mm) of cover (NEC Table 300.5). Several details, such as the drum traps, reflect older or non-US practice, so check them against the plumbing code before you use them in current construction. Coordinate these blocks with the architectural plans early: shafts, trenches and equipment rooms are far cheaper to move on paper.

Each block downloads as a DWG and a DXF in inches and millimeters. For presentation boards, client decks or a quick sketch over a photo, the same drawing also comes as a PDF, a PNG with a transparent background and an SVG vector.

Frequently asked questions

Are drum traps allowed under US plumbing codes?

Generally not for fixtures installed today. The International Plumbing Code lists drum traps among prohibited traps, except as solids interceptors or for chemical waste (IPC 1002.3). Use the drum trap blocks for surveys of older buildings; for current work, draw a standard P-trap.

How deep must buried electrical conduit be?

In most locations NEC Table 300.5 calls for 24″ (610 mm) of cover over direct-burial cable, 18″ (457 mm) over PVC conduit and 6″ (152 mm) over rigid metal conduit, with reductions under concrete. The electrical conduit trench section is a base for the trench detail and the backfill notes.

Where should a fire extinguisher be mounted?

NFPA 10 puts the top of an extinguisher weighing up to 40 lb (18 kg) no higher than 5′ (1524 mm), heavier units no higher than 3½′ (1067 mm), and the bottom at least 4″ (102 mm) off the floor. Travel distance to a Class A extinguisher is limited to 75′ (22.9 m).

What is the difference between a bottle trap and a P-trap?

A bottle trap holds its water seal in a compact cylinder under the basin, a neat look under pedestal and wall-hung sinks; a P-trap is a curved pipe. Both must keep a 2–4″ (51–102 mm) seal, and not every jurisdiction accepts bottle traps, so confirm before you specify the bottle trap.

Which fire protection blocks are there?

A fire extinguisher, a fire hose cabinet and a fire hydrant in front elevation, for wall elevations and site plans, plus the matching fire extinguisher sign and fire hose reel sign in Symbols & signs for the life safety plan.

Can I get these mep: plumbing & electrical blocks as PNG or SVG?

Yes. Every block here also downloads as a PNG with a transparent background, an SVG vector and a PDF, from its own page, next to the DWG and DXF.